Terrace PU membrane, heat reflective coating, drain redesign

Hotels cannot close during tourist season. We worked in zones — flood test each section before membrane, heat-reflective coat to cut AC load on top floor. Competitors offered acrylic re-coat in two days. We mapped leak paths first; active cracks got PU injection before membrane.

Outcome: Guest room leak complaints eliminated